| Cooling capacityThe range of cooling capacities this model is available in — the cooling delivered, not the electricity used. Which one suits a room depends on a heat-load assessment of that room, not on floor area alone. | 2.5 kW | 2.5 kW | 3.5 kW | 3.5 kW | 4.6 kW | 4.6 kW | 5.0 kW | 5.0 kW | 6.1 kW | 6.1 kW | 7.0 kW | 7.0 kW |
|---|
| Heating capacityPresent when the system can heat as well as cool. In heating mode it works as a heat pump, moving heat in from the outside air rather than creating all of it. | 3.2 kW | 3.2 kW | 4.2 kW | 4.2 kW | 5.5 kW | 5.5 kW | 6.0 kW | 6.0 kW | 7.0 kW | 7.0 kW | 8.0 kW | 8.0 kW |
|---|
| Series | RAS SHORAI Curve | RAS SHORAI Curve | RAS SHORAI Curve | RAS SHORAI Curve | RAS SHORAI Curve | RAS SHORAI Curve | RAS SHORAI Curve | RAS SHORAI Curve | RAS SHORAI Curve | RAS SHORAI Curve | RAS SHORAI Curve | RAS SHORAI Curve |
|---|
| System typeHow the system is put together. A single split serves one room from one outdoor unit. A multi-split serves several indoor units from one outdoor unit. VRF — variable refrigerant flow — is the larger commercial version, where one outdoor unit serves many indoor units that can run independently of each other. | Single split | Single split | Single split | Single split | Single split | Single split | Single split | Single split | Single split | Single split | Single split | Single split |
|---|
| Indoor unit style | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted | Wall-mounted |
|---|
| Efficiency, cooling (SEER)How efficiently each system cools across a typical season, as published by the manufacturer. A higher number normally means the same cooling for less electricity, which makes this the fairest single row for comparing two systems of similar capacity. It is not a prediction of a bill — that also depends on the building and how the system is used. | 8.6 | 8.6 | 8.6 | 8.6 | 7.8 | 7.8 | 7.3 | 7.3 | 7.3 | 7.3 | 6.3 | 6.3 |
|---|
| Efficiency, heating (SCOP)The same idea as the row above, but for heating across a typical season: higher generally means more heat for each unit of electricity used. Present only where the system can heat. | 5.1 | 5.1 | 5.1 | 5.1 | 4.6 | 4.6 | 4.6 | 4.6 | 4.6 | 4.6 | 4.1 | 4.1 |
|---|
| Energy labelAs printed by the manufacturer. The scale differs by capacity band, so two labels are only comparable within the same band. | A+++ / A+++ | A+++ / A+++ | A+++ / A+++ | A+++ / A+++ | A++ / A++ | A++ / A++ | A++ / A++ | A++ / A++ | A++ / A++ | A++ / A++ | A++ / A+ | A++ / A+ |
|---|
| Sound leveldB(A) is a measurement of sound, and the scale is not a straight line — a difference of a few dB(A) is more noticeable than the numbers suggest. Manufacturers quote under their own test conditions, so treat these as a guide to relative quietness rather than as directly comparable numbers. | 19 dB(A) in Quiet mode, up to 41 dB(A) at full speed. Measured as the manufacturer publishes it: Quiet, from "Sound pressure level (high/quiet)" in the current SHORAI Curve brochure (12/2025-A). Cooling 41/19, heating 40/19. High, from "Sound pressure level (high/quiet)". Cooling 41/19, heating 40/19. | 19 dB(A) in Quiet mode, up to 41 dB(A) at full speed. Measured as the manufacturer publishes it: Quiet, from "Sound pressure level (high/quiet)" in the current SHORAI Curve brochure (12/2025-A). Cooling 41/19, heating 40/19. High, from "Sound pressure level (high/quiet)". Cooling 41/19, heating 40/19. | 19 dB(A) in Quiet mode, up to 43 dB(A) at full speed. Measured as the manufacturer publishes it: Quiet, from "Sound pressure level (high/quiet)" in the current SHORAI Curve brochure (12/2025-A). Cooling 43/19, heating 43/19. High, from "Sound pressure level (high/quiet)". Cooling 43/19, heating 43/19. | 19 dB(A) in Quiet mode, up to 43 dB(A) at full speed. Measured as the manufacturer publishes it: Quiet, from "Sound pressure level (high/quiet)" in the current SHORAI Curve brochure (12/2025-A). Cooling 43/19, heating 43/19. High, from "Sound pressure level (high/quiet)". Cooling 43/19, heating 43/19. | 22 dB(A) in Quiet mode, up to 44 dB(A) at full speed. Measured as the manufacturer publishes it: Quiet, from "Sound pressure level (high/quiet)" in the current SHORAI Curve brochure (12/2025-A). Cooling 44/22, heating 44/22. High, from "Sound pressure level (high/quiet)". Cooling 44/22, heating 44/22. | 22 dB(A) in Quiet mode, up to 44 dB(A) at full speed. Measured as the manufacturer publishes it: Quiet, from "Sound pressure level (high/quiet)" in the current SHORAI Curve brochure (12/2025-A). Cooling 44/22, heating 44/22. High, from "Sound pressure level (high/quiet)". Cooling 44/22, heating 44/22. | 26 dB(A) in Quiet mode, up to 44 dB(A) at full speed. Measured as the manufacturer publishes it: Quiet, from "Sound pressure level (high/quiet)" in the current SHORAI Curve brochure (12/2025-A). Cooling 44/26, heating 44/26. High, from "Sound pressure level (high/quiet)". Cooling 44/26, heating 44/26. | 26 dB(A) in Quiet mode, up to 44 dB(A) at full speed. Measured as the manufacturer publishes it: Quiet, from "Sound pressure level (high/quiet)" in the current SHORAI Curve brochure (12/2025-A). Cooling 44/26, heating 44/26. High, from "Sound pressure level (high/quiet)". Cooling 44/26, heating 44/26. | 27 dB(A) in Quiet mode, up to 46 dB(A) at full speed. Measured as the manufacturer publishes it: Quiet, from "Sound pressure level (high/quiet)" in the current SHORAI Curve brochure (12/2025-A). Cooling 46/27, heating 46/27. High, from "Sound pressure level (high/quiet)". Cooling 46/27, heating 46/27. | 27 dB(A) in Quiet mode, up to 46 dB(A) at full speed. Measured as the manufacturer publishes it: Quiet, from "Sound pressure level (high/quiet)" in the current SHORAI Curve brochure (12/2025-A). Cooling 46/27, heating 46/27. High, from "Sound pressure level (high/quiet)". Cooling 46/27, heating 46/27. | 28 dB(A) in Quiet mode, up to 47 dB(A) at full speed. Measured as the manufacturer publishes it: Quiet, from "Sound pressure level (high/quiet)" in the current SHORAI Curve brochure (12/2025-A). Cooling 47/28, heating 48/28. High, from "Sound pressure level (high/quiet)". Cooling 47/28, heating 48/28. | 28 dB(A) in Quiet mode, up to 47 dB(A) at full speed. Measured as the manufacturer publishes it: Quiet, from "Sound pressure level (high/quiet)" in the current SHORAI Curve brochure (12/2025-A). Cooling 47/28, heating 48/28. High, from "Sound pressure level (high/quiet)". Cooling 47/28, heating 48/28. |
|---|
| Indoor sound pressureSound pressure is how loud the indoor unit is at a stated distance — the figure closest to what you would actually hear. This is the quietest each manufacturer quotes, measured under its own conditions; see the row above. | 19 dB(A) | 19 dB(A) | 19 dB(A) | 19 dB(A) | 22 dB(A) | 22 dB(A) | 26 dB(A) | 26 dB(A) | 27 dB(A) | 27 dB(A) | 28 dB(A) | 28 dB(A) |
|---|
| Smart / Wi-Fi control | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
|---|
| Air purification | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) |
|---|
| Draught-free modeCooling without a direct air stream, which manufacturers name differently — Samsung's is WindFree™. | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
|---|
| Refrigerant | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 | R32 |
|---|
| Colour | White | Black | White | Black | White | Black | White | Black | White | Black | White | Black |
|---|
| Indoor unit dimensions | 822 × 293 × 226 mm (width × height × depth) | 822 × 293 × 226 mm (width × height × depth) | 822 × 293 × 226 mm (width × height × depth) | 822 × 293 × 226 mm (width × height × depth) | 822 × 293 × 226 mm (width × height × depth) | 822 × 293 × 226 mm (width × height × depth) | 1076 × 320 × 248 mm (width × height × depth) | 1076 × 320 × 248 mm (width × height × depth) | Not confirmed | Not confirmed | 1076 × 320 × 248 mm (width × height × depth) | 1076 × 320 × 248 mm (width × height × depth) |
|---|
| Filtration | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) | Ultra-Pure filter (PM2.5 94%) |
|---|
| Residential or commercial | Residential, Heat pumps | Residential, Heat pumps | Residential, Heat pumps | Residential, Heat pumps | Residential, Heat pumps | Residential, Heat pumps | Residential, Heat pumps | Residential, Heat pumps | Residential, Heat pumps | Residential, Heat pumps | Residential, Heat pumps | Residential, Heat pumps |
|---|
| InstallationHow much work a typical installation involves. The hours depend on the building, which is why this is a band and not a price. | StandardIndicative guidance | StandardIndicative guidance | StandardIndicative guidance | StandardIndicative guidance | StandardIndicative guidance | StandardIndicative guidance | StandardIndicative guidance | StandardIndicative guidance | StandardIndicative guidance | StandardIndicative guidance | StandardIndicative guidance | StandardIndicative guidance |
|---|
| Indicative positioningWhere each model sits in the range. Not a quality judgement — the right choice depends on the room and the budget. | Mid-RangeIndicative guidance | Mid-RangeIndicative guidance | Mid-RangeIndicative guidance | Mid-RangeIndicative guidance | Mid-RangeIndicative guidance | Mid-RangeIndicative guidance | Mid-RangeIndicative guidance | Mid-RangeIndicative guidance | Mid-RangeIndicative guidance | Mid-RangeIndicative guidance | Mid-RangeIndicative guidance | Mid-RangeIndicative guidance |
|---|